Navigation

Related Products

Quick View

S272CD Online Process pH Sensor

Product Description
The S272CD online process pH sensor delivers reliable online monitoring for in-line or submersion installation configuration. This sensor is designed to extend sensor lifetime with double-junction technology. Minimal maintenance required due to flat glass measurement surface. A versatile sensor for moderate and multi-purpose applications.
  • Reliable performance in demanding applications: Liquid flow naturally cleans the flat pH measurement surface
  • Extended sensor lifetime: Double junction technology extends sensor lifetime by preventing reference contamination
  • Versatile design for many applications: 3/4″ NPT threads on both ends for submersion or in-line mounting
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

PC-100 pH/ORP Panel Meter

The PC-100 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installation. The PC-100 features for sample monitoring.
Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics process
Features
  1. 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
  2. Sensor slope performance diagnosis & error message
  3. User-friendly operation
  4. Automatic temperature compensation
  5. Compatible with Pt-1000 and NTC 30K temperature probe
  6. Isolated current output DC 0/4~20mA
  7. Gradually continuous sample measurements average function to enhance stability
Quick View

PC-110 pH/ORP Panel Meter

Compact and Pragmatic
The PC-110 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installaion. The PC-100 features for sample monitoring and the PC-110 offers one relay output to sufficiently activate your process system.
Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics process
Features
  1. 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
  2. Sensor slope performance diagnosis & error message
  3. User-friendly operation
  4. Automatic temperature compensation
  5. Compatible with Pt-1000 and NTC 30K temperature probe
  6. Isolated current output DC 0/4~20mA
  7. Gradually continuous sample measurements average function to enhance stability
  8. PC-110 offers one relay contact output, one set point with programmable hysteresis function
Quick View

ORP3000 Research Grade ORP Electrode

Product Description
In harsh laboratory or field conditions, where heat, moisture, or corrosive chemicals may damage equipment, ORP electrode durability is key. The ORP3000 is durable, research grade ORP electrode. All the functional components – the ORP measurement surface, the meter connection, and the cable connection – are reinforced with protective elements. Durable Ultem® body construction provides extensive chemical compatibility and withstands temperatures up to 100°C.
  • Virtually unbreakable: removable guard protects ORP measurement surface and strain relief prevents damage to cable connection
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • No maintenance required: Sealed gel reference design does not require users to refill solution
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ready for wet or corrosive environments: BNC boot protects meter connection
Quick View

PC-3310-RS Intelligent pH/ORP Transmitter

Intelligence Advanced Graphics, RS-485 Modbus, 1/2 DIN, IP65
  1. 144 x 144mm Intelligent pH/ORP Transmitter
  2. Waterproof and dustproof design
  3. Solution-ground design eliminating interference of ground potential
  4. Large LCM with auto-sense backlight and contrast setting function
  5. User-friendly operation with text and graphic illustration, clear signs and easy to understand
  6. Multi-Cal calibration, Tech. and NIST buffer automatic recognition
  7. Max. 3-point calibration and the calibration line calculated by linear regression, the last calibration data displayable
  8. With password and multi-key design-security protection enhancement
  9. Automatic temperature compensation, NTC30K or PT 1000 selectable
  10. Two sets of isolated current output at DC 0/4~20mA, max. load 500Ω
  11. Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis
  12. Gradually continuous sample measurements average function to enhance stability
  13. Automatic sensor clean function with programmable time interval
  14. LED indicated alarm or washing status signal
  15. IP 65 (NEMA 4X)
Quick View

AquaSense

Swimming pools and spas use chlorine as a disinfectant and so use an analyzer to control the amount of chlorine that gets dosed. The AquaSense Swimming Pool Controller and Spa Controller measures the pool chlorine levels and the pH of the pool and then controls the chlorine and pH levels by controlling the chemical dosing. The AquaSense offers bufferless and reagentless operation and is suitable for commercial, municipal and community swimming pools. The AquaSense has been designed to three criteria:
  • Improved Safety – better sensors lead to better process control which leads to less variation in chlorine residuals even with highly variable bathing load.
  • Improved Control – better process control leads to reduced chemical usage, lower costs and an improved bathing experience.
  • Reduced Costs – lower chemical costs, less expensive controllers, inverter control leading to hugely reduced electrical usage costs are just a few of the ways that the AquaSense can save you money which can pay for a new controller in just a few months.
Key Benefits
  • Inverter control for massive electricity and CO2 savings
  • Stable and reliable residual chlorine and pH measurement and control
  • Low purchase cost
  • Low cost of ownership
  • SMS text alarms
  • Remote access via Internet
  • Suitable for fresh water, salt water and outdoor pools with cyanuric acid
  • Private label option for re-sellers
  • Other inputs to data log and alarms
Quick View

SoliSense®

Key Benefits
  • From 2 NTU to 8% Solids
  • Displays in NTU, mg/l, g/l or % solids – flexible
  • Auto-clean optical sensor – months without maintenance
  • Stable and reliable – excellent process control
  • Suitable for all potable, waste and process waters
  • Up to 12 months between maintenance
  • Up to 12 months between calibration
The SoliSense® suspended solids sensor is available with different controllers giving you the same great performance with different communication, display, and control options. With the SoliSense® range of online suspended solids analyzers, you get everything that you need – and nothing that you don’t, without sacrificing the quality of measurement. The use of a single sensor to robustly and accurately measure a large dynamic range of suspended solids allows for:
  • Less spares – more commonality across a single or multiple sites
  • No requirement to know the range prior to specifying – easier purchasing
  • One online suspended solids analyzer can be:
    • Online mlss meter
    • Online tss meter
    • Online total suspended solids meter
    • Online effluent monitor
    • Online inlet monitor
    • Online ‘in process’ suspended solids analyzer
Quick View

FluoriSense

Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.
  • Measuring method: ISE (Ion Specific Electrode)
  • Measure range: 0.02 ppm saturation
  • Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
  • Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
  • Electrode resistance: less than 50 MΩ
  • Reproducibility: ±2%
  • Cable length: 100cm
  • Calibration: Manual using test kit
  • No reagent required
Quick View

PC-3100 Series Microprocessor pH/ORP Transmitter

Robust protection and precise integration

The PC-3100 series pH/ORP transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions.

Applications
Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage process
Features
  1. pH, ORP, Temperature measurement
  2. IP 65 waterproof and dustproof design
  3. Back-lit LCD with ON/OFF/Auto programmable illumination
  4. Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature
  5. Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function
  6. Automatic temperature compensation
  7. Gradually continuous sample measurements average function to enhance stability
  8. Wash function with programmable time-interval control
  9. LED indication alarm or wash status signal
  10. Password protection
  11. PC-3100RS with one analog output and one RS-485 interface
Quick View

TurbSense®

Key Benefits
The TurbSense® online turbidity meters are available with different controllers giving you the same great performance with different communication, display, and control options. With the TurbSense® range of online turbidity meters, you get everything that you need – and nothing that you don’t, without sacrificing the quality of the measurement. The online turbidity meters from Pi are now in use around the world providing trouble free, easy to use solutions to a range of online turbidity monitoring and control.
  • Autoclean solid state optical sensor – no moving parts
  • Single point calibration – very easy to use
  • Stable and reliable – excellent process control
  • Suitable for all potable, waste and process waters between 0 NTU and 1000 NTU
  • ‘Maintenance free’ – low cost of ownership
  • No ‘zero’ required – improved accuracy at the low end
  • Up to 1 year between calibration – very little drift
  • Up to 10 bar – for inline operation
  • 0.001 resolution
  • Automatic debubbling and bubble removal solutions – no interference from bubbles
Back to top