pH2200 Spear Tip Plastic pH Sensor

Product Description
Looking to measure the pH of soil, meat, or cheese? A standard pH sensor with bulb shaped glass won’t effectively pierce the surface of these semi-solids; the pH glass may even crack. That’s why we’ve created the pH2200 spear tip pH sensor, specially designed to penetrate semi-solid surfaces for effective pH measurement. The sensor is assembled with a bio-friendly Ultem® body, making it safe for use in food and soil. Use this durable pH sensor at home or in the field with any pH meter accepting a BNC connector.
  • Rugged spear tip measurement surface for piercing semi-solid samples
  • Bio-friendly Ultem® body for safe measurements in food and soil
  • Long-lasting with built-in protection against protein contamination
  • No refilling or maintenance required with sealed gel-filled design
  • Instantly ready for use and shipped in storage bottle for long shelf life
Quick View

DioSense

Key Benefits
The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.
  • Amperometric sensors – continuous online chlorine dioxide ppm measurement
  • No chemical reagents – lower cost of ownership
  • Stable and reliable – excellent process control
  • Suitable for all potable and process waters
  • Up to 6 months between maintenance
  • No interference from residual chlorine (DioSense M)
  • Tolerant of water containing detergents
  • Up to 70°C (DioSense NM)
  • Up to 6 Bar (DioSense NM)
Quick View

FluoriSense

Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.
  • Measuring method: ISE (Ion Specific Electrode)
  • Measure range: 0.02 ppm saturation
  • Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
  • Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
  • Electrode resistance: less than 50 MΩ
  • Reproducibility: ±2%
  • Cable length: 100cm
  • Calibration: Manual using test kit
  • No reagent required
Quick View

BioSense

Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.
  • Legionella control
  • Automatic Biocide control
  • Can be combined with other sensors
  • No maintenance
  • Cooling towers and any water circuit
  • Seawater option Reduced chemical costs Up to 10 Bar
Quick View

S272CD Online Process pH Sensor

Product Description
The S272CD online process pH sensor delivers reliable online monitoring for in-line or submersion installation configuration. This sensor is designed to extend sensor lifetime with double-junction technology. Minimal maintenance required due to flat glass measurement surface. A versatile sensor for moderate and multi-purpose applications.
  • Reliable performance in demanding applications: Liquid flow naturally cleans the flat pH measurement surface
  • Extended sensor lifetime: Double junction technology extends sensor lifetime by preventing reference contamination
  • Versatile design for many applications: 3/4″ NPT threads on both ends for submersion or in-line mounting
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

ORPSense

Key Benefits
The ORPSense range of ORP Meters from Pi utilize the very latest and best ORP sensors available in the world today for measuring the online Redox potential of any aqueous solution. They are platinum ball based sensors with integral reference electrodes which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs. Online ORP meters and ORP controllers are one of the most common analyzers in use today in water treatment and process plants and yet online ORP meters cause continual problems for their operators. What is needed is a stable, reliable, online ORP meter for a reasonable cost. That is exactly what you get with the ORPSense and the ORPSense Automatic Calibrator. The ORPSense sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and control options. With the ORPSense range of ORP meters, you get everything that you need – and nothing that you don’t.
    Stable and reliable ORP meter On board diagnostics Low purchase cost Long life ORP sensors Remote access and SMS text alarms PID and other process controls
Quick View

pH2100 Flat Tip Plastic pH Electrode

Product Description
Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical pH glass bulb due to concerns about breakage. To facilitate these and other surface measurements, we created the pH2100 flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids.
  • Ideal for surface measurements and slurries: rugged flat measurement tip resists breakage
  • Great for testing unknown sample types: double junction electrode reference design prevents contamination
  • Durable and Versatile: Ultem® body offers enhanced chemical compatibility and booted BNC protects meter connection
  • No maintenance required: sealed gel filled reference design
  • One year limited warranty: We stand by our products with the Sensorex guarantee
Quick View

SG-2110-RS Intelligent Specific Gravity Transmitter

Applications
Electronics industry Chemical industry
Features
  1. Waterproof and dustproof design
  2. 96 x 96mm microprocessor Specific Gravity/Baumé/Salinity/ Concentration transmitter
  3. Measuring unit: SG/°Bé/ ppt/ %
  4. User-friendly operation with text and graphic illustration, clear signs and easy to understand
  5. Measuring value can be selected for figure or chart display
  6. Trace mode can display historical measured value curve from 3-minute to 4-week program
  7. Equipped with logbook function
  8. Large LCM display with auto-sense backlight and contrast setting function
  9. Built-in Specific gravity - Concentration conversion table for setting, up to 10 points
  10. Cell constant, Pure water, Known solution— 3 types calibration
  11. Simultaneous display of measurement value and temperature
  12. Automatic temperature compensation for setting
  13. Equipped with one analog output DC 0/4~20mA, Max.500Ω and RS-485 interface
  14. Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis
  15. With password and multi-key design, enhanced security protection
  16. LED indicated alarm
  17. IP 65 (NEMA 4X)
Specific Gravity Sensor
Load Cell & plummet principle High accuracy & long lifetime of reliability Wide range measurement Anti-acid gas design
Quick View

HaloSense Zero

Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
  • Low purchase cost
  • Low cost of ownership
  • Reduced pH dependency (largely pH independent)
  • Stable and reliable
  • Bufferless
  • Reagentless
Quick View

ConductiSense

The ConductiSense range of online conductivity meters from Pi utilize the very latest and best conductivity sensors available in the world today for measuring the online conductivity of any aqueous solution. Online conductivity meters are common in today’s water treatment and process plants. ConductiSense is a stable, reliable, online conductivity meter for a reasonable cost. The ConductiSense sensors and accessories are available with different controllers giving you the same great performance with different communication, display, and control options. With the ConductiSense range of Conductivity Monitors, you get everything that you need – and nothing that you don’t.
Key Benefits
  • Resists coating, corrosion and fouling
  • Durable Noryl (plastic) construction
  • Easy installation
  • Low purchase cost
  • Custom tee for in-line mounting