Navigation

Related Products

Quick View

ORP2000 Extended Life ORP Sensor

Product Description
When measuring samples such as wastewaster that may contain proteins, heavy metals, or other contaminants, it is important to use an ORP sensor (REDOX sensor) designed to withstand unpredictable chemical environments. The ORP2000 features double junction reference protection, which prevents contamination by sample components that interact with silver (Ag). The durable Ultem® body ensures extensive chemical compatibility, making the ORP2000 a highly versatile analytical tool.
  • Virtually unbreakable with durable Ultem® body construction and recessed protected glass
  • Reliable and accurate ORP / REDOX measurements
  • No refilling or maintenance required with sealed gel-filled design
  • Instantly ready for use and shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty
Quick View

BioSense

Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.
  • Legionella control
  • Automatic Biocide control
  • Can be combined with other sensors
  • No maintenance
  • Cooling towers and any water circuit
  • Seawater option Reduced chemical costs Up to 10 Bar
Quick View

HaloSense Zero

Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
  • Low purchase cost
  • Low cost of ownership
  • Reduced pH dependency (largely pH independent)
  • Stable and reliable
  • Bufferless
  • Reagentless
Quick View

DioSense

Key Benefits
The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.
  • Amperometric sensors – continuous online chlorine dioxide ppm measurement
  • No chemical reagents – lower cost of ownership
  • Stable and reliable – excellent process control
  • Suitable for all potable and process waters
  • Up to 6 months between maintenance
  • No interference from residual chlorine (DioSense M)
  • Tolerant of water containing detergents
  • Up to 70°C (DioSense NM)
  • Up to 6 Bar (DioSense NM)
Quick View

pH2000 Extended Life Laboratory Plastic pH Sensor

Product Description
Applications such as environmental and wastewater sampling involve some uncertainty about what samples may contain. When dealing with unknown or unpredictable sample types, you need a durable pH probe you can trust to deliver accurate measurements regardless of the contaminants you encounter. The pH2000 has a double junction reference design to prevent reference fouling by heavy metals and other sample contaminants. When you travel to remote sites to collect data, it is especially important that obtaining the measurements you need is hassle free. The pH2000 features an Ultem® body and a booted meter connection for durability in the field. The sealed reference design requires no maintenance. Compatible with any meter accepting a BNC connector.
  • Durable and low maintenance: Ultem® body construction, reinforced meter connection, and sealed reference design
  • Great for testing unknown sample types: Double junction reference protection prevents reference cell contamination
  • Accurate measurements across full pH scale (0-14)
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • Compatible with any meter accepting a BNC connector
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

TurbSense®

Key Benefits
The TurbSense® online turbidity meters are available with different controllers giving you the same great performance with different communication, display, and control options. With the TurbSense® range of online turbidity meters, you get everything that you need – and nothing that you don’t, without sacrificing the quality of the measurement. The online turbidity meters from Pi are now in use around the world providing trouble free, easy to use solutions to a range of online turbidity monitoring and control.
  • Autoclean solid state optical sensor – no moving parts
  • Single point calibration – very easy to use
  • Stable and reliable – excellent process control
  • Suitable for all potable, waste and process waters between 0 NTU and 1000 NTU
  • ‘Maintenance free’ – low cost of ownership
  • No ‘zero’ required – improved accuracy at the low end
  • Up to 1 year between calibration – very little drift
  • Up to 10 bar – for inline operation
  • 0.001 resolution
  • Automatic debubbling and bubble removal solutions – no interference from bubbles
Quick View

pH3000 Research-Grade Plastic pH Sensor (Refillable)

Product Description
When accuracy and repeatability are critical, such as in pharmaceutical or drinking water applications, the ideal pH electrode will quickly deliver stable measurements. The pH3000 is a research grade pH meter replacement probe specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals also make these electrodes the best choice for low ionic samples. The double junction reference design prevents contamination, allowing pH testing in samples containing heavy metals, proteins and enzymes, or TRIS buffer.
  • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
  • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • Virtually unbreakable: removable bulb guard protects pH glass and strain relief prevents damage to cable connection
  • Ready for wet or corrosive environments: BNC boot protects meter connection
  • Compatible with various meters: Versatile replacement probe works with any meter accepting a BNC pH probe
Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples, samples containing heavy metals
Quick View

PC-100 pH/ORP Panel Meter

The PC-100 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installation. The PC-100 features for sample monitoring.
Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics process
Features
  1. 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
  2. Sensor slope performance diagnosis & error message
  3. User-friendly operation
  4. Automatic temperature compensation
  5. Compatible with Pt-1000 and NTC 30K temperature probe
  6. Isolated current output DC 0/4~20mA
  7. Gradually continuous sample measurements average function to enhance stability
Quick View

pH1400 Light Duty Glass pH Electrode

Product Description
Whether you are a student measuring pH in a lab or a business owner monitoring plant or crop health, you need a pH probe that will consistently deliver accurate measurements. If you deal with a wide variety of chemicals or any aggressive substances, a glass pH probe like our pH1400 is a safe choice due to the chemically inert properties of glass. This basic, single junction electrode has a refillable reference cell, allowing users to maintain measurement precision throughout instrument lifetime.
  • Accurate measurements across full pH scale (0-14)
  • Easily maximize measurement repeatability: refillable reference cell with liquid solution
  • Maximum chemical compatibility: glass probe body is inert to most reactions
  • Compatible with a variety of pH meters: use this probe with any pH meter accepting BNC
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

FT520 Batch Flow Processor

Product Description
The FT500-Series is a batching flow processor with additional output controls. It is designed for use with Seametrics flow meters and flow sensors, as well as other manufacturer’s products which have frequency output proportional to flow. In addition to batch functions, the FT500- Series indicates flow rate, and other data in large 3/8” (9.66 mm) digits on an easily-read, backlit display. Units of measure are user selectable, and range from milliliters per second to millions of gallons per day. The unit can be 110 Vac powered with a standard 3-wire cord (included), 220 Vac powered (optional), or DC powered through an internal terminal strip. An analog output of 4-20 mA is available both in active and passive loop configuration, and in 0-5 Vdc or 0-10 Vdc outputs, and can be used in applications such as flow rate logging. Two programmable pulse scaled outputs are also standard, and can be used, for example, to provide proportional chemical feed with a pulse-responsive metering pump. The housing is supplied with two brackets for wall-mount applications, or the top/bottom housings can be easily separated and reassembled for panel-mount.
  • Large backlit alphanumeric display
  • Built-in 4-20 mA analog output
  • User-scaled pulse output for chemical metering pumps or telemetry
  • Two relay outputs for staged shutoff (batching) or dual setpoints (alarm option)
  • Rugged cast aluminum housing
  • Wall or panel mounting
Back to top