Navigation

Related Products

Quick View

pH2100 Flat Tip Plastic pH Electrode

Product Description
Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical pH glass bulb due to concerns about breakage. To facilitate these and other surface measurements, we created the pH2100 flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids.
  • Ideal for surface measurements and slurries: rugged flat measurement tip resists breakage
  • Great for testing unknown sample types: double junction electrode reference design prevents contamination
  • Durable and Versatile: Ultem® body offers enhanced chemical compatibility and booted BNC protects meter connection
  • No maintenance required: sealed gel filled reference design
  • One year limited warranty: We stand by our products with the Sensorex guarantee
Quick View

FT520 Batch Flow Processor

Product Description
The FT500-Series is a batching flow processor with additional output controls. It is designed for use with Seametrics flow meters and flow sensors, as well as other manufacturer’s products which have frequency output proportional to flow. In addition to batch functions, the FT500- Series indicates flow rate, and other data in large 3/8” (9.66 mm) digits on an easily-read, backlit display. Units of measure are user selectable, and range from milliliters per second to millions of gallons per day. The unit can be 110 Vac powered with a standard 3-wire cord (included), 220 Vac powered (optional), or DC powered through an internal terminal strip. An analog output of 4-20 mA is available both in active and passive loop configuration, and in 0-5 Vdc or 0-10 Vdc outputs, and can be used in applications such as flow rate logging. Two programmable pulse scaled outputs are also standard, and can be used, for example, to provide proportional chemical feed with a pulse-responsive metering pump. The housing is supplied with two brackets for wall-mount applications, or the top/bottom housings can be easily separated and reassembled for panel-mount.
  • Large backlit alphanumeric display
  • Built-in 4-20 mA analog output
  • User-scaled pulse output for chemical metering pumps or telemetry
  • Two relay outputs for staged shutoff (batching) or dual setpoints (alarm option)
  • Rugged cast aluminum housing
  • Wall or panel mounting
Quick View

ORP3000 Research Grade ORP Electrode

Product Description
In harsh laboratory or field conditions, where heat, moisture, or corrosive chemicals may damage equipment, ORP electrode durability is key. The ORP3000 is durable, research grade ORP electrode. All the functional components – the ORP measurement surface, the meter connection, and the cable connection – are reinforced with protective elements. Durable Ultem® body construction provides extensive chemical compatibility and withstands temperatures up to 100°C.
  • Virtually unbreakable: removable guard protects ORP measurement surface and strain relief prevents damage to cable connection
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • No maintenance required: Sealed gel reference design does not require users to refill solution
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ready for wet or corrosive environments: BNC boot protects meter connection
Quick View

pH3000 Research-Grade Plastic pH Sensor (Refillable)

Product Description
When accuracy and repeatability are critical, such as in pharmaceutical or drinking water applications, the ideal pH electrode will quickly deliver stable measurements. The pH3000 is a research grade pH meter replacement probe specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals also make these electrodes the best choice for low ionic samples. The double junction reference design prevents contamination, allowing pH testing in samples containing heavy metals, proteins and enzymes, or TRIS buffer.
  • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
  • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • Virtually unbreakable: removable bulb guard protects pH glass and strain relief prevents damage to cable connection
  • Ready for wet or corrosive environments: BNC boot protects meter connection
  • Compatible with various meters: Versatile replacement probe works with any meter accepting a BNC pH probe
Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples, samples containing heavy metals
Quick View

StreamerSense

Key Benefits
  • Immediate response to process changes in coagulation treatment – coagulation monitor
  • Maintain high quality finished water through improved coagulation control –coagulation controller
  • Reduce coagulant/polymer costs – coagulant analyzer
  • Automate dosing coagulant/polymer dosing using the streaming current monitor –coagulant control
  • Ensure coagulation reliability – coagulant analyzer
  • Improve operator efficiency – coagulant analyzer
  • Improve filter performance and coagulation treatment – coagulation controller
  • Monitor your coagulation control process – coagulation monitor
Streaming Current Monitors Standard Features
  • Patented sensor design
  • Quick replacement probe and piston
  • Self-diagnostic sensor
  • High-volume flow minimizes sensor fouling
  • Removes electronics from harsh environments
  • Corrosion-free Nema 4x enclosure (IP65)
  • Optional computer interface
  • Spare probe cartridge and piston included
  • Auxiliary input signals
Quick View

pH2000 Extended Life Laboratory Plastic pH Sensor

Product Description
Applications such as environmental and wastewater sampling involve some uncertainty about what samples may contain. When dealing with unknown or unpredictable sample types, you need a durable pH probe you can trust to deliver accurate measurements regardless of the contaminants you encounter. The pH2000 has a double junction reference design to prevent reference fouling by heavy metals and other sample contaminants. When you travel to remote sites to collect data, it is especially important that obtaining the measurements you need is hassle free. The pH2000 features an Ultem® body and a booted meter connection for durability in the field. The sealed reference design requires no maintenance. Compatible with any meter accepting a BNC connector.
  • Durable and low maintenance: Ultem® body construction, reinforced meter connection, and sealed reference design
  • Great for testing unknown sample types: Double junction reference protection prevents reference cell contamination
  • Accurate measurements across full pH scale (0-14)
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • Compatible with any meter accepting a BNC connector
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

HaloSense Zero

Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
  • Low purchase cost
  • Low cost of ownership
  • Reduced pH dependency (largely pH independent)
  • Stable and reliable
  • Bufferless
  • Reagentless
Quick View

pH2500 Flat Surface Glass pH Electrode

Product Description
Surfaces like paper, leather, electrophoresis gels and agar plates may be difficult to measure with traditional pH glass bulbs due to concerns about breakage. A flat electrode like our pH2500, is ideally suited for these types of pH measurements as well as measurements of suspended sludges and slurries. In addition to its specially designed measurement surface, the pH2500 features double junction construction, which prevents contamination and allows testing of samples containing heavy metals or proteins.
  • Perfect for gels and slurries: Flat electrode measurement surface designed for testing special sample types
  • Accurate measurements across full pH scale (0-14)
  • Highly adaptable: Compatible with any pH meter accepting BNC
  • Low maintenance: Gel-filled electrode reference design with double junction to prevent contamination
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

DioSense

Key Benefits
The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.
  • Amperometric sensors – continuous online chlorine dioxide ppm measurement
  • No chemical reagents – lower cost of ownership
  • Stable and reliable – excellent process control
  • Suitable for all potable and process waters
  • Up to 6 months between maintenance
  • No interference from residual chlorine (DioSense M)
  • Tolerant of water containing detergents
  • Up to 70°C (DioSense NM)
  • Up to 6 Bar (DioSense NM)
Quick View

UV254Sense

Key Benefits
  • UVA (ultra-violet absorbance) is an excellent surrogate parameter for TOC, DOC, COD and color.
  • UVT (ultra-violet transmission) allows for the calculation of optimal UV dose for disinfection systems, improving efficiency.
  • Accurate detection without the cost of reagents.
  • Few ongoing service or maintenance requirements.
  • Allows feed forward optimization of coagulation control, resulting in decreases in chemical consumption, reduction in sludge removal costs and minimization of DBP formation potential.
  • Strong ROI with pay back on the analyzer being seen by many customers within a few months.
  • UVA measurement ensures performance of various contaminant removal technologies such as membranes (RO, NF, UF), ion exchange (nitrates and TOC removal) and granular activated carbon (GAC).
  • Real time UVA analyzers can provide a final check of effluent water quality and can alarm an operator in case of non-compliance.
  • A UVA monitor can monitor the percentage removal of organics across any treatment system.
  • Can be combined with a CRONOS® or CRIUS® for a multi-parameter UV254 analyzer solution that suits your needs.
  • Standard Features
  • Online continuous operation
  • Patent pending Ortho-Beam technology
  • 254nm wavelength UV light source
  • Displays UV transmittance or absorbance values
  • Back to top