Navigation

Related Products

Quick View

ORP2000 Extended Life ORP Sensor

Product Description
When measuring samples such as wastewaster that may contain proteins, heavy metals, or other contaminants, it is important to use an ORP sensor (REDOX sensor) designed to withstand unpredictable chemical environments. The ORP2000 features double junction reference protection, which prevents contamination by sample components that interact with silver (Ag). The durable Ultem® body ensures extensive chemical compatibility, making the ORP2000 a highly versatile analytical tool.
  • Virtually unbreakable with durable Ultem® body construction and recessed protected glass
  • Reliable and accurate ORP / REDOX measurements
  • No refilling or maintenance required with sealed gel-filled design
  • Instantly ready for use and shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty
Quick View

ORP1000 Polycarbonate Laboratory ORP Sensor

Product Description
The ORP1000 is a durable and easy to use ORP sensor. Great for outdoor applications, such as monitoring swimming pool chlorine, this probe has built in protection for the ORP sensor surface. Use the ORP1000 with any ORP meter accepting a BNC connector.
  • Very fast response time: Platinum measurement surface for fast response time and stable readings
  • No maintenance required: Sealed reference design requires no refilling
  • Durable construction: Polycarbonate body is built for frequent lab or field use
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

PC-3100 Series Microprocessor pH/ORP Transmitter

Robust protection and precise integration

The PC-3100 series pH/ORP transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions.

Applications
Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage process
Features
  1. pH, ORP, Temperature measurement
  2. IP 65 waterproof and dustproof design
  3. Back-lit LCD with ON/OFF/Auto programmable illumination
  4. Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature
  5. Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function
  6. Automatic temperature compensation
  7. Gradually continuous sample measurements average function to enhance stability
  8. Wash function with programmable time-interval control
  9. LED indication alarm or wash status signal
  10. Password protection
  11. PC-3100RS with one analog output and one RS-485 interface
Quick View

BioSense

Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.
  • Legionella control
  • Automatic Biocide control
  • Can be combined with other sensors
  • No maintenance
  • Cooling towers and any water circuit
  • Seawater option Reduced chemical costs Up to 10 Bar
Quick View

ConductiSense

The ConductiSense range of online conductivity meters from Pi utilize the very latest and best conductivity sensors available in the world today for measuring the online conductivity of any aqueous solution. Online conductivity meters are common in today’s water treatment and process plants. ConductiSense is a stable, reliable, online conductivity meter for a reasonable cost. The ConductiSense sensors and accessories are available with different controllers giving you the same great performance with different communication, display, and control options. With the ConductiSense range of Conductivity Monitors, you get everything that you need – and nothing that you don’t.
Key Benefits
  • Resists coating, corrosion and fouling
  • Durable Noryl (plastic) construction
  • Easy installation
  • Low purchase cost
  • Custom tee for in-line mounting
Quick View

pH2500 Flat Surface Glass pH Electrode

Product Description
Surfaces like paper, leather, electrophoresis gels and agar plates may be difficult to measure with traditional pH glass bulbs due to concerns about breakage. A flat electrode like our pH2500, is ideally suited for these types of pH measurements as well as measurements of suspended sludges and slurries. In addition to its specially designed measurement surface, the pH2500 features double junction construction, which prevents contamination and allows testing of samples containing heavy metals or proteins.
  • Perfect for gels and slurries: Flat electrode measurement surface designed for testing special sample types
  • Accurate measurements across full pH scale (0-14)
  • Highly adaptable: Compatible with any pH meter accepting BNC
  • Low maintenance: Gel-filled electrode reference design with double junction to prevent contamination
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

UV254Sense

Key Benefits
  • UVA (ultra-violet absorbance) is an excellent surrogate parameter for TOC, DOC, COD and color.
  • UVT (ultra-violet transmission) allows for the calculation of optimal UV dose for disinfection systems, improving efficiency.
  • Accurate detection without the cost of reagents.
  • Few ongoing service or maintenance requirements.
  • Allows feed forward optimization of coagulation control, resulting in decreases in chemical consumption, reduction in sludge removal costs and minimization of DBP formation potential.
  • Strong ROI with pay back on the analyzer being seen by many customers within a few months.
  • UVA measurement ensures performance of various contaminant removal technologies such as membranes (RO, NF, UF), ion exchange (nitrates and TOC removal) and granular activated carbon (GAC).
  • Real time UVA analyzers can provide a final check of effluent water quality and can alarm an operator in case of non-compliance.
  • A UVA monitor can monitor the percentage removal of organics across any treatment system.
  • Can be combined with a CRONOS® or CRIUS® for a multi-parameter UV254 analyzer solution that suits your needs.
  • Standard Features
  • Online continuous operation
  • Patent pending Ortho-Beam technology
  • 254nm wavelength UV light source
  • Displays UV transmittance or absorbance values
  • Quick View

    pH3400 Research Grade Glass pH Electrode

    Product Description
    In laboratory environments such as medical, biological, and materials science research groups, samples and test conditions are constantly changing, but accuracy is always critical. The pH3400 is a highly versatile glass combination pH electrode, specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals allow testing of low ionic samples. Safely measure samples containing heavy metals, TRIS buffer, or proteins thanks to the double junction reference design, which prevents fouling. Even test highly reactive chemicals: with a glass body, the pH3400 is inert to a wide range of chemical reactions.
    • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
    • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
    • Safe for use with reactive chemicals: Glass bodies are inert to many chemical reactions
    • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
    • Ready for wet or corrosive environments: BNC boot protects meter connection
    Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples (including TRIS buffer), samples containing heavy metals
    Quick View

    DioSense

    Key Benefits
    The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.
    • Amperometric sensors – continuous online chlorine dioxide ppm measurement
    • No chemical reagents – lower cost of ownership
    • Stable and reliable – excellent process control
    • Suitable for all potable and process waters
    • Up to 6 months between maintenance
    • No interference from residual chlorine (DioSense M)
    • Tolerant of water containing detergents
    • Up to 70°C (DioSense NM)
    • Up to 6 Bar (DioSense NM)
    Quick View

    HaloSense Zero

    Key Benefits
    Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
    • Low purchase cost
    • Low cost of ownership
    • Reduced pH dependency (largely pH independent)
    • Stable and reliable
    • Bufferless
    • Reagentless
    Back to top