Navigation

Ternary Liquid Analysers – 9500 Series

‹Return to Previous Page

Related Products

Quick View

PC-3100 Series Microprocessor pH/ORP Transmitter

Robust protection and precise integration

The PC-3100 series pH/ORP transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions.

Applications
Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage process
Features
  1. pH, ORP, Temperature measurement
  2. IP 65 waterproof and dustproof design
  3. Back-lit LCD with ON/OFF/Auto programmable illumination
  4. Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature
  5. Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function
  6. Automatic temperature compensation
  7. Gradually continuous sample measurements average function to enhance stability
  8. Wash function with programmable time-interval control
  9. LED indication alarm or wash status signal
  10. Password protection
  11. PC-3100RS with one analog output and one RS-485 interface
Quick View

FluoriSense

Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.
  • Measuring method: ISE (Ion Specific Electrode)
  • Measure range: 0.02 ppm saturation
  • Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
  • Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
  • Electrode resistance: less than 50 MΩ
  • Reproducibility: ±2%
  • Cable length: 100cm
  • Calibration: Manual using test kit
  • No reagent required
Quick View

pH2500 Flat Surface Glass pH Electrode

Product Description
Surfaces like paper, leather, electrophoresis gels and agar plates may be difficult to measure with traditional pH glass bulbs due to concerns about breakage. A flat electrode like our pH2500, is ideally suited for these types of pH measurements as well as measurements of suspended sludges and slurries. In addition to its specially designed measurement surface, the pH2500 features double junction construction, which prevents contamination and allows testing of samples containing heavy metals or proteins.
  • Perfect for gels and slurries: Flat electrode measurement surface designed for testing special sample types
  • Accurate measurements across full pH scale (0-14)
  • Highly adaptable: Compatible with any pH meter accepting BNC
  • Low maintenance: Gel-filled electrode reference design with double junction to prevent contamination
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

pH2400 Extended Life Glass pH Electrode

Product Description
Environmental, wastewater, and other sampling applications may expose electrodes to unknown contaminants. Over time, exposure to contaminants such as heavy metals and reactive chemicals, will take a toll on a sensor’s functional components. The best sensors for these types of applications are built to safely handle contaminants to maximize working lifetime. Our pH2400 is a glass electrode with double junction reference design to prevent fouling by sample contaminants that interact with Silver (Ag). The refillable reference junction allows users to replace the liquid fill solution as it becomes depleted or contaminated, instead of replacing the whole sensor.
  • Accurate measurements across full pH scale (0-14)
  • Maximum chemical compatibility: glass electrode bodies are inert to most reactions
  • Extended lifetime: Refillable reference junction allows sensor maintenance, saving replacement costs
  • Great for wet or corrosive environments: BNC boot protects meter connection
  • Compatible with any meter accepting BNC
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

pH1400 Light Duty Glass pH Electrode

Product Description
Whether you are a student measuring pH in a lab or a business owner monitoring plant or crop health, you need a pH probe that will consistently deliver accurate measurements. If you deal with a wide variety of chemicals or any aggressive substances, a glass pH probe like our pH1400 is a safe choice due to the chemically inert properties of glass. This basic, single junction electrode has a refillable reference cell, allowing users to maintain measurement precision throughout instrument lifetime.
  • Accurate measurements across full pH scale (0-14)
  • Easily maximize measurement repeatability: refillable reference cell with liquid solution
  • Maximum chemical compatibility: glass probe body is inert to most reactions
  • Compatible with a variety of pH meters: use this probe with any pH meter accepting BNC
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

HaloSense Zero

Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
  • Low purchase cost
  • Low cost of ownership
  • Reduced pH dependency (largely pH independent)
  • Stable and reliable
  • Bufferless
  • Reagentless
Quick View

SoliSense®

Key Benefits
  • From 2 NTU to 8% Solids
  • Displays in NTU, mg/l, g/l or % solids – flexible
  • Auto-clean optical sensor – months without maintenance
  • Stable and reliable – excellent process control
  • Suitable for all potable, waste and process waters
  • Up to 12 months between maintenance
  • Up to 12 months between calibration
The SoliSense® suspended solids sensor is available with different controllers giving you the same great performance with different communication, display, and control options. With the SoliSense® range of online suspended solids analyzers, you get everything that you need – and nothing that you don’t, without sacrificing the quality of measurement. The use of a single sensor to robustly and accurately measure a large dynamic range of suspended solids allows for:
  • Less spares – more commonality across a single or multiple sites
  • No requirement to know the range prior to specifying – easier purchasing
  • One online suspended solids analyzer can be:
    • Online mlss meter
    • Online tss meter
    • Online total suspended solids meter
    • Online effluent monitor
    • Online inlet monitor
    • Online ‘in process’ suspended solids analyzer
Quick View

pHSense

The pHSense range of online pH meters from Pi utilize the very latest and best pH sensors available in the world today for measuring the online pH of any aqueous solution. They are patented gel filled sensors with integral reference which uses no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs. The junction, usually the source of error with current pH sensor technology is made from an electrochemically active solid resulting in a more robust pH sensor. Online pH meters and pH controllers are one of the most common analyzers in use today in water treatment and process plants and yet online pH meters cause continual problems for their operators. What is needed is a stable, reliable, online pH meter for a reasonable cost. That is exactly what you get with the pHSense. The pHSense sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and control options. With the pHSense range of online pH meters, you get everything that you need – and nothing that you don’t.
Key Benefits
Stable and reliable online pH meter On board diagnostics Auto calibrant recognition Low purchase cost Long life pH sensors Remote access and SMS text alarms
Quick View

pH3000 Research-Grade Plastic pH Sensor (Refillable)

Product Description
When accuracy and repeatability are critical, such as in pharmaceutical or drinking water applications, the ideal pH electrode will quickly deliver stable measurements. The pH3000 is a research grade pH meter replacement probe specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals also make these electrodes the best choice for low ionic samples. The double junction reference design prevents contamination, allowing pH testing in samples containing heavy metals, proteins and enzymes, or TRIS buffer.
  • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
  • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • Virtually unbreakable: removable bulb guard protects pH glass and strain relief prevents damage to cable connection
  • Ready for wet or corrosive environments: BNC boot protects meter connection
  • Compatible with various meters: Versatile replacement probe works with any meter accepting a BNC pH probe
Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples, samples containing heavy metals
Quick View

UV254Sense

Key Benefits
  • UVA (ultra-violet absorbance) is an excellent surrogate parameter for TOC, DOC, COD and color.
  • UVT (ultra-violet transmission) allows for the calculation of optimal UV dose for disinfection systems, improving efficiency.
  • Accurate detection without the cost of reagents.
  • Few ongoing service or maintenance requirements.
  • Allows feed forward optimization of coagulation control, resulting in decreases in chemical consumption, reduction in sludge removal costs and minimization of DBP formation potential.
  • Strong ROI with pay back on the analyzer being seen by many customers within a few months.
  • UVA measurement ensures performance of various contaminant removal technologies such as membranes (RO, NF, UF), ion exchange (nitrates and TOC removal) and granular activated carbon (GAC).
  • Real time UVA analyzers can provide a final check of effluent water quality and can alarm an operator in case of non-compliance.
  • A UVA monitor can monitor the percentage removal of organics across any treatment system.
  • Can be combined with a CRONOS® or CRIUS® for a multi-parameter UV254 analyzer solution that suits your needs.
  • Standard Features
  • Online continuous operation
  • Patent pending Ortho-Beam technology
  • 254nm wavelength UV light source
  • Displays UV transmittance or absorbance values
  • Back to top